This is a
1. Hold F1 to choose interface for Add or Remove Z-Wave network.
2. Click F2 five times until arrows icon turns blue
3. Hold F2 and the device enters into learning mode, then radio icon turns blue and the device is added into Z-Wave network.
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
MCOHome A8-9 is a Z-Wave enabled multiple environmental monitoring sensor, with 3.5 inch TFT clear display and compliant to Z-Wave Plus standard. It is built in with Temperature, Humidity, PM2.5, CO2, VOC, PIR, illumination, Noise, Smoke sensor. Device can be added into any Z-Wave network, and is compatible with any other Z-Wave certified devices.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
1. Press & hold F1 to enter Z-Wave setting interface, then press & hold F1 again to enter parameters setting interface
2. Press & hold F2 to enter setting interface and select default
3. Click F2 3 times and displays OFF-->ON-->OK-->OFF, factory setting is restored.
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
Device is suggested to be installed indoor, a place with around 1.5m height above the floor where represents the average CO2 concentration. It should be away from direct sunlight, any cover, or any heat source, to avoid false signal for temperature control.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Power on/off
Wire the adaptor and the device is powered on. It will display all detected information by the sensors.
Display interface
Hold Key F1 can switch among the following 4 display interfaces:
1. Data detecting: display all sensors data
2. Network: Z-Wave Add/Remove
3. Data calibration: to calibrate the detected data manually
4. Local time setting
Data Calibration
1. Hold F1 to choose interface for data calibration.
2. Then hold F2 to switch among the sensors.
3. Choose one and click F2, F1 to change the data.
4. After finished, hold F1 can return data detecting interface.
Local time setting
1. Hold F1 to choose interface for local time setting.
2. Then hold F2 to switch among Hour-Minute-Second-Year-Month-Date.
3. Click F2, F1 can change the data of flashing item.
4. After finished, hold F1 can return data detecting interface.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Lifeline group |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
This is the PM2.5 Delta Level which determine when to report the current PM2.5 value. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Indicates Turn off report |
1 - 127 | Indicates to report current PM2.5 value when change >n * 1ug/m3 |
This is the CO2 Delta Level which determines when to report the current CO2 value. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Indicates Turn off report |
1 - 127 | Indicates to report current CO2 value when change > n * 5ppm |
This is the temperature Delta Level which determines when to report the current temperature value. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Indicates Turn off report |
1 - 127 | Indicates to report current temperature value when change > n * 0.5 |
This is the humidity Delta Level which determines when to report the current humidity value. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Indicates Turn off report |
1 - 127 | Indicates to report current humidity value when change >n% |
This is the VOC Delta Level which determines when to report the current VOC value. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Indicates Turn off report |
1 - 127 | n*5ppb Report change |
This is the brightness Delta Level which determines when to report the current brightness value. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Indicates Turn off report |
1 - 32767 | Indicates to report current Illumination value when change >n*1 Lux |
This is the noise Delta Level which determines when to report the current noise value. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Indicates Turn off report |
1 - 127 | Indicates to report current Noise value when change >n*1 dB |
This is the temperature Delta Level which determines when to report the current temperature value. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Indicates Turn off report |
1 | Indicates report change |
Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Indicates Turn off report |
1 | Indicates report change |
Size: 2 Byte, Default Value: 60
Setting | Description |
---|---|
0 | Turn off report |
35 - 32767 | Report every n*1s |
Size: 2 Byte, Default Value: 60
Setting | Description |
---|---|
0 | Turn off report |
35 - 32767 | Report every n*1s |
Size: 2 Byte, Default Value: 120
Setting | Description |
---|---|
0 | Turn off report |
35 - 32767 | Report every n*1s |
Size: 2 Byte, Default Value: 120
Setting | Description |
---|---|
0 | Turn off report |
35 - 32767 | Report every n*1s |
Size: 2 Byte, Default Value: 180
Setting | Description |
---|---|
0 | Turn off report |
35 - 32767 | Report every n*1s |
Size: 2 Byte, Default Value: 180
Setting | Description |
---|---|
0 | Turn off report |
35 - 32767 | Report every n*1s |
Size: 2 Byte, Default Value: 180
Setting | Description |
---|---|
0 | Turn off report |
35 - 32767 | Report every n*1s |
Size: 2 Byte, Default Value: 300
Setting | Description |
---|---|
0 | Turn off report |
35 - 32767 | Report every n*1s |
Size: 2 Byte, Default Value: 300
Setting | Description |
---|---|
0 | Turn off report |
35 - 32767 | Report every n*1s |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | °C |
1 | °F |
Size: 1 Byte, Default Value: 100
Setting | Description |
---|---|
0 - 127 | ((n-100)/10)=(-10~2.7)℃ |
-128 (255) - -1 (128) | ((156+n)/10)=(2.8~15.5)℃ |
Size: 2 Byte, Default Value: 20
Setting | Description |
---|---|
0 - 40 | n-20=(-20~20)% |
Size: 2 Byte, Default Value: 500
Setting | Description |
---|---|
0 - 1000 | (n-500)=(-500~500)ppm |
Size: 1 Byte, Default Value: 100
Setting | Description |
---|---|
0 - 127 | n-100=(-100~27)ug/m3 |
-128 (255) - -1 (128) | 156+n=(28~155)ug/m3 |
Size: 2 Byte, Default Value: 5000
Setting | Description |
---|---|
0 - 10000 | n-5000=(-5000~5000)lux |
Size: 1 Byte, Default Value: 100
Setting | Description |
---|---|
0 - 127 | n-100=(-100~27)ppb |
-128 (255) - -1 (128) | 156+n=(28~155)ppb |
Size: 1 Byte, Default Value: 50
Setting | Description |
---|---|
0 - 100 | (n-50)=-50~50 |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
85 | Factory Reset |
170 | Restore default Parameter |
Dimensions | 0.1090000x0.1090000x0.0420000 mm |
Weight | 397 gr |
Hardware Platform | ZM5202 |
EAN | 4251295702551 |
IP Class | IP 20 |
Voltage | 12 V |
Device Type | Notification Sensor |
Network Operation | Always On Slave |
Z-Wave Version | 6.71.03 |
Certification ID | ZC10-20096971 |
Z-Wave Product Id | 0x015F.0xA803.0x135A |
Color | White |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |