This is a
| Reset to factory default | Press 10 times of UP or DOWN button or exclude the device from Z-Wave network, then cut off the main power. The factory setting will be restored. |
| Inclusion | 1. Power the panel on, if LEDs flick 4 times, it shows the device is not in any Z-Wave network. If LEDs turns to orange directly, the panel is in a network already.
2. Set controller into Include/Exclude mode, and press 8 seconds or 3 clicks on "UP" or "DOWN" button to add/remove. If succeed, green LED flicks 4 times. |
| Exclusion | 1. Power the panel on, if LEDs flick 4 times, it shows the device is not in any Z-Wave network. If LEDs turns to orange directly, the panel is in a network already.
2. Set controller into Include/Exclude mode, and press 8 seconds or 3 clicks on "UP" or "DOWN" button to add/remove. If succeed, green LED flicks 4 times. |
| NIF | XXXNIF |
| Wakeup | XXXWakeupDescription |
| Protection | XXXProtection |
| FirmwareUpdate | XXXFirmwareUpdate |
| SetAssociation | XXXSetAssociation |
| Group Number | Maximum Nodes | Description |
|---|---|---|
| 1 | 1 | Lifeline |
Size: 2 Byte, Default Value: 720
| Setting | Description |
|---|---|
| 1 - 32767 | Unit 5sec 5*720S=3600S= 1hour |
Size: 2 Byte, Default Value: 6
| Setting | Description |
|---|---|
| 1 - 32767 | Unit 10min 6*10min=1 hour |
Size: 1 Byte, Default Value: 2
| Setting | Description |
|---|---|
| 1 | Report destination level in 5s period when requested by the gateway; And then report current level after 5s. |
| 2 | Report every 10% level change while running |
Size: 1 Byte, Default Value: 0
| Setting | Description |
|---|---|
| 1 | activate demo trip only |
Size: 1 Byte, Default Value: 10
| Setting | Description |
|---|---|
| 0 | LED disabled |
| 1 - 10 | Min level-Max level |
| 11 - 255 | same level as 10 |
Size: 1 Byte, Default Value: 0
| Setting | Description |
|---|---|
| 1 | activate demo trip and calibration |
Size: 1 Byte, Default Value: 0
| Setting | Description |
|---|---|
| 1 | activate calibration |
Size: 1 Byte, Default Value: 0
| Setting | Description |
|---|---|
| 0 - 98 | in % |
Size: 1 Byte, Default Value: 99
| Setting | Description |
|---|---|
| 1 - 99 | in % |
Size: 1 Byte, Default Value: 0
| Setting | Description |
|---|---|
| 85 | Factory Reset |
| Dimensions | 0.0860000x0.0860000x0.0420000 mm |
| Weight | 163 gr |
| Hardware Platform | ZM5202 |
| EAN | 6928954214004 |
| IP Class | IP 20 |
| Voltage | 230 V |
| Load | 2x 3,5 A |
| Device Type | Window Covering Position/Endpoint Aware |
| Generic Device Class | Multilevel Switch |
| Specific Device Class | Motor Control Device (C) |
| Firmware Version | 03.02 |
| Z-Wave Version | 04.3e |
| Z-Wave Product Id | 0x015f.0xc321.0x5102 |
| Frequency | Europe - 868,4 Mhz |
| Maximum transmission power | 5 mW |