This is a
To confirm Inclusion and Exclusion press and hold the User Button on the door lock until it beeps twice.
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
The ZEC 100 Danalock is a smart lock from Poly Control to upgrade your existing door lock. You will need no more key to lock or unlock your door. With the Danalock you can control your door lock with a Z-Wave Controller or via Z-Wave Gateway with your Smartphone. From insde the room you can operate the lock by touching the user button.
Within the scope of delivery you will get a Danalock cylinder to replace the existing cylinder of your door lock. You will also get the main device with the battery and the assisted motor and a screwdriver for mounting. The cylinder is applied for european doors.
Scope of Delivery:
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
To reset the device press and hold the User Button on the door lock until it beeps ten times.
The product contains batteries. Please remove the batteries when the device is not used. Do not mix batteries of different charging level or different brands.
The ZEC 100 smart lock is for indoor use only. It is installed at the inner side of the door and replaces the normal lock cylinder.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
To confirm Inclusion and Exclusion press and hold the User Button on the door lock until it beeps twice.
To confirm Inclusion and Exclusion press and hold the User Button on the door lock until it beeps twice.
To open the door from outside you can use an associated Z-Wave controller or a smartphone together with a Z-Wave IP-Gateway. In addition you can open the lock conventionally with the normal keys.
From inside you can open the lock via Z-Wave or by touching the User Button.
The color of the LED Grid shows the lock status: Green for opened, Red for locked.
The Node Information Frame (NIF) is the business card of a Z-Wave device. It contains information about the device type and the technical capabilities. The inclusion and exclusion of the device is confirmed by sending out a Node Information Frame. Beside this it may be needed for certain network operations to send out a Node Information Frame. To issue a NIF execute the following action:
To issue a Node Information Frame press and hold the User Button on the door lock until it beeps twice.
This device is battery operated and turned into deep sleep state most of the time to save battery life time. Communication with the device is limited. In order to communicate with the device, a static controller C is needed in the network. This controller will maintain a mailbox for the battery operated devices and store commands that can not be received during deep sleep state. Without such a controller, communication may become impossible and/or the battery life time is significantly decreased.
This device will wakeup regularly and announce the wakeup state by sending out a so called Wakeup Notification. The controller can then empty the mailbox. Therefore, the device needs to be configured with the desired wakeup interval and the node ID of the controller. If the device was included by a static controller this controller will usually perform all necessary configurations. The wakeup interval is a tradeoff between maximal battery life time and the desired responses of the device. To wakeup the device please perform the following action:
To wake up the device manually press and hold the User Button on the door lock until it beeps twice.
Here are a few hints for network installation if things dont work as expected.
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
parameter defines which direction the motor turns the lock in relation to the latch
Size: 1 Byte, Default Value: 00
Setting | Description |
---|---|
00 | Clockwise when latching |
01 | Counterclockwise when latching |
parameter defines whether the motor goes slower (more torque) or faster (less torque) when turning the lock
Size: 1 Byte, Default Value: 03
Setting | Description |
---|---|
01 | Slowest Speed, Strongest Torque |
02 | Slow Speed, Stronger Torque |
03 | Normal Speed,Normal Torque |
04 | Fast Speed, Weak Torque |
05 | Fastest Speed, Weakest Torque |
parameter defines if more or less torque is used at latch/unlatch operations (less torque safes power)
Size: 1 Byte, Default Value: 01
Setting | Description |
---|---|
00 | Less torque, Power Saving mode |
01 | Normal Mode |
parameter defines how many degrees the lock turns at latch/unlatch operations
Size: 1 Byte, Default Value: 09
Setting | Description |
---|
parameter defines amount of seconds after opening the door automatically locks again
Size: 1 Byte, Default Value: 00
Setting | Description |
---|---|
00 | Disabled |
01 - 3c | delay after opening in seconds |
parameter defines if an acoustic signal confirms latch/unlatch operations
Size: 1 Byte, Default Value: 01
Setting | Description |
---|---|
00 | Latch/unlatch Sound disabled |
01 | Latch/unlatch Sound enabled |
parameter defines the battery type (voltage) is used to power the device value shouldnt be changed!
Size: 1 Byte, Default Value: 01
Setting | Description |
---|---|
00 | 3.6 volt battery type |
01 | 3.0 volt battery type |
parameter defines the percent battery status threshold underrun which leads to an acoustic signal after latch/unlatch operations
Size: 1 Byte, Default Value: 1e
Setting | Description |
---|
Dimensions | 0.0800000x0.0800000x0.0500000 mm |
Weight | 385 gr |
EAN | 5712560101039 |
Battery Type | 4 * CR123 |
Firmware Version | 02.04 |
Z-Wave Version | 02.4e |
Z-Wave Product Id | 010e.0003.0002 |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |