This is a
This little sensor and protect any kind of moving or shaking parts from misuse and theft. It measures acceleration in all three dimensions and will issue an alarm when the device is moved or shaken. Possible applications are doors that are not supposed ot be opened regularlay, trash bins, only certain people are allowed to use or certan furniture that requires special protection.
The device can be installed on every flat and dry surface. If needed use double sided tape to screws to mount the device. Please note that touching the sensor will issue an alarm when the device is armed. The device must be initially armed once placed on the final location. Double click the button for arming. The red LED will blick for few seconds until the greed LED confirms that armign was successful.
Once the device is installed and armed every acceleration of the device in any direction will issue a notification alarm (Z-Wave Alarm No. 7) into the lifeline. Low battery notifications are also reported into the lifeline.
Reset to factory default | Push button for 10 seconds |
Inclusion | Single Click the button |
Exclusion | Single Click the button |
NIF | Single Click the button |
Wakeup | Single Click the button |
Protection | XXXProtection |
FirmwareUpdate | ??? |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Lifeline |
This parameter defines the threshold for the acceleration sensor to trip. Please note that there is always movement, e.g. by cars driving by. Setting this value too low will therefore issue lots of wrong alarms and drain the battery. Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 - 250 | x 4 mg |
This parameter defines the time the sensr will automatically reset the alarm condition (and stay armed) once there is no further movement detected. Size: 1 Byte, Default Value: 20
Setting | Description |
---|---|
0 - 250 | Seconds |
The device can be armed/disamed using the standard Z-Wave function for alarm asming/disarming. Arming is always spossible with double clicking the button. Manual disarming behavior depends on the setting of this parameter Size: 3 Byte, Default Value: 0
Setting | Description |
---|---|
0 | No Manual Disarming |
1 | Manual Disarming by two seconds push of button |
Dimensions | 34x34x16 mm mm |
Weight | 80 gr |
Hardware Platform | ZM5101 |
IP Class | IP 20 |
Battery Type | 1 * CR2477 |
Device Type | Notification Sensor |
Network Operation | Sleeping Sensor |
Firmware Version | 00.00 |
Z-Wave Version | 06.01 |
Z-Wave Product Id | 0154.0000.0000 |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |