1. Start the add mode on the Z-Wave controller. See the controllers manual.
2. Remove both magnets from Strips. Strips blinks twice to confirm the command and successful addition.
3. A long LED blink indicates that the add process was successful
4. The Z-Wave controller application should now allow you to monitor your Strips sensor status.
5. Move the squared magnet as shown in the picture . Check that the Z-Wave system indicates the status correctly
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Strip Drip sends an alarm signal if it detects a water leak. Its unique design allows it to be easily placed almost everywhere, including most places other sensors simply can?t fit. With soaking pads integrated in the mounting plate even small amounts of water will be detected. The built-in temperature sensor gives the possibility to combine the leakage alarm with a freeze alarm. There is also a built-in ambient light sensor that may be useful in special applications.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
Bewegen Sie den Magneten an die abgerundete Kante, und sobald die LED blinkt, bewegen Sie den Magneten weg, und lassen Sie ihn bei der dritten Wiederholung 10 Sekunden lang wie in der Abbildung unten (20 mm von der abgerundeten Kante entfernt) stehen.
The product contains batteries. Please remove the batteries when the device is not used. Do not mix batteries of different charging level or different brands.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Please note that poor network reliability will affect Strips Drip battery life. When Strips Drip blinks 5 times, this indicates that Strips Drip failed to communicate with the controller. If it happens frequently you may move the controller closer or add an extender between the controller and Strips Drip.
LED LIGHT SIGNALS
This device is battery operated and turned into deep sleep state most of the time to save battery life time. Communication with the device is limited. In order to communicate with the device, a static controller C is needed in the network. This controller will maintain a mailbox for the battery operated devices and store commands that can not be received during deep sleep state. Without such a controller, communication may become impossible and/or the battery life time is significantly decreased.
This device will wakeup regularly and announce the wakeup state by sending out a so called Wakeup Notification. The controller can then empty the mailbox. Therefore, the device needs to be configured with the desired wakeup interval and the node ID of the controller. If the device was included by a static controller this controller will usually perform all necessary configurations. The wakeup interval is a tradeoff between maximal battery life time and the desired responses of the device. To wakeup the device please perform the following action: Wake up Strips manually for Z-Wave communication:1. Place the round magnet at the rounded edge of Strips. 2. When the LED blinks, move the magnet away. 3. Repeat 3 times in total within 10 seconds.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Z-Wave Plus Lifeline |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Off |
1 | On |
Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 | Normal |
2 | Frequent |
(Does not affect temperature alarms) Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Off |
1 | On |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Celsius |
1 | Fahrenheit |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Off |
1 | On |
Size: 1 Byte, Default Value: 60
Setting | Description |
---|---|
0 - 60 | Value in °C (0 - 60°C) |
236 - 255 | Value in °C (-20 - -1) |
Size: 1 Byte, Default Value: 236
Setting | Description |
---|---|
0 - 60 | Value in °C (0 - 60°C) |
236 - 255 | Value in °C (-20 - -1) |
Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Off |
1 | On |
2 | Report only when levels defined in parameter 10 & 11 are passed. |
Size: 4 Byte, Default Value: 40000
Setting | Description |
---|---|
3 - 64 000 | Value in LUX |
(Must be significantly lower than parameter 10) Size: 4 Byte, Default Value: 5000
Setting | Description |
---|---|
1 - 42000 | Value in LUX |
Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Off |
1 | On |
Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
1 - 100 | Leakage alarm level 1 = almost dry, 100 = wet |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Off |
1 - 120 | Hours between reports |
Dimensions | 15 x 195 x 3 mm |
Weight | 10 gr |
Hardware Platform | ZM5101 |
EAN | 7350088520093 |
IP Class | IP 65 |
Battery Type | 1 * 3,0 V LiMnO2 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Z-Wave Version | 6.51.06 |
Certification ID | ZC10-16045049 |
Z-Wave Product Id | 0x019A.0x0003.0x0003 |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |