Quickstart

This is a secure Alarm Sensor for CEPT (Europe). Please make sure the internal battery is fully charged. To add this device to your network execute the following action:
Auto inclusion1. Use a screwdriver to detach the battery cover.2. Put the AXIS M5065 camera (or other Z-Wave controller) into inclusion mode.3. Insert 1 CR123 3V batteries into the battery compartment with the correct polarity. The LED on the device should turn ON4. Enter PIN number into the Z-Wave controller. The PIN number can be found on the device. See where in the installationguide.5. The inclusion process should be completed when the LED stops blinking6. Perform test before you refit the battery cover. See How to test the Z-Wave Device.Manual inclusion1. Use a screwdriver to detach the battery cover.2. Put the AXIS M5065 camera (or other Z-Wave controller) into inclusion mode.3. Insert 1 CR123 3V batteries into the battery compartment with the correct polarity. The LED on the device should turn ON4. Press the tamper switch 3 times within 1.5 seconds to put the unit into learning (inclusion/exclusion) mode.5. Enter PIN number into the Z-Wave controller. The PIN number can be found on the device. See where in the installationguide.6. The inclusion process should be completed when the LED stops blinking.7. Perform test before you refit the battery cover. See How to test the Z-Wave Device.

Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.


Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.

This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.

If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.

Product Description

AXIS T8341-EUR PIR Motion Sensor is a wireless sensor which provides motion detection both day and night. With its support for wireless input/output connectivity, the PIR motion sensor can communicate wirelessly with AXIS M5065 PTZ Network camera or other connected Z-Wave Plus controllers, creating a small security solution with less cabling. Thanks to its integrated wireless I/O connectivity, AXIS T8341-EUR enables flexible installation as the sensor can easily be moved and adapted to your needs.

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.

Reset to factory default

This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.

1. Press the tamper switch 3 times within 1.5 seconds to put the device into exclusion mode.2. Within 1 second of step 1, press the tamper switch again and hold until LED is off (about 5 seconds).3. Node ID is excluded. The device reverts to factory default state and will be in auto-inclusion mode for 4 minutes.(This procedure should only be used when the controller is notresponding.)

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.

Inclusion

Auto inclusion1. Use a screwdriver to detach the battery cover.2. Put the AXIS M5065 camera (or other Z-Wave controller) into inclusion mode.3. Insert 1 CR123 3V batteries into the battery compartment with the correct polarity. The LED on the device should turn ON4. Enter PIN number into the Z-Wave controller. The PIN number can be found on the device. See where in the installationguide.5. The inclusion process should be completed when the LED stops blinking6. Perform test before you refit the battery cover. See How to test the Z-Wave Device.Manual inclusion1. Use a screwdriver to detach the battery cover.2. Put the AXIS M5065 camera (or other Z-Wave controller) into inclusion mode.3. Insert 1 CR123 3V batteries into the battery compartment with the correct polarity. The LED on the device should turn ON4. Press the tamper switch 3 times within 1.5 seconds to put the unit into learning (inclusion/exclusion) mode.5. Enter PIN number into the Z-Wave controller. The PIN number can be found on the device. See where in the installationguide.6. The inclusion process should be completed when the LED stops blinking.7. Perform test before you refit the battery cover. See How to test the Z-Wave Device.

Exclusion

Manual exclusion1. Use a screwdriver to detach the battery cover.2. Press the tamper switch 3 times within 1.5 seconds to put the unit into learning (inclusion/exclusion) mode.3. The exclusion process should be completed when the LED stops blinking4. Refit the battery cover.

Communication to a Sleeping device (Wakeup)

This device is battery operated and turned into deep sleep state most of the time to save battery life time. Communication with the device is limited. In order to communicate with the device, a static controller C is needed in the network. This controller will maintain a mailbox for the battery operated devices and store commands that can not be received during deep sleep state. Without such a controller, communication may become impossible and/or the battery life time is significantly decreased.

This device will wakeup regularly and announce the wakeup state by sending out a so called Wakeup Notification. The controller can then empty the mailbox. Therefore, the device needs to be configured with the desired wakeup interval and the node ID of the controller. If the device was included by a static controller this controller will usually perform all necessary configurations. The wakeup interval is a tradeoff between maximal battery life time and the desired responses of the device. To wakeup the device please perform the following action: After the detector has been included into a Z-Wave network it will go to sleep, but it will send a wake-up notification commandto the controller periodically at a preset period . The motion detector will stay awake for at least 10 seconds and then go back tosleep to conserve battery life.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association - one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.

Association Groups:

Group Number Maximum Nodes Description
1 1 Association with 1 node.
2 4 Association with 4 nodes.

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.

IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.

Parameter 1: Basic set level

When a Basic Set Command is sent and contains a value, the receiver will process it. For example, a lamp module would receive a Basic Set command which determines the dim level.
Size: 1 Byte, Default Value: 99

Setting Description
1 - 99 Basic set level can be set 1~99.

Parameter 3: Sensitivity level

For optimal efficiency, it is recommended to test the detectors response to movements from the farthest end of the coverage area when you use it for the first time. If movements cannot be detected accurately, simply adjust the sensitivity level with the Configuration Parameter #3. This parameter can be configured with a value from 1 to 10, where 1 means low sensitivity and 10 means highest sensitivity.
Size: 1 Byte, Default Value: 6

Setting Description
1 - 10 Sensitivity level can be set 1~10.

Parameter 4: Re-trigger interval setting

The configuration parameter used to adjust the re-trigger interval after the detector has been triggered as configuration parameter #4. No response will be made during this interval if a movement is detected. The time interval can be set between 5 seconds to 3,600 seconds.
Size: 2 Byte, Default Value: 180

Setting Description
5 - 3600 Re-trigger interval can be set 5~3600 seconds.

Parameter 5: Lux level

You can set a percentage for the lux level which determines when the light sensor will be activated. If the ambient illumination drops below the set percentage, and a person moves across or within the protected area, the detector will emit a Z-Wave ON command (i.e. Basic Set command (Value = Basic Set Level)) to the controller and activate connected modules and lighting. The percentage can be set between 1% to 100%.
Size: 1 Byte, Default Value: 20

Setting Description
1 - 100 Lux level can be set 1~100%.

Parameter 6: On-off duration

The on-off duration setting can be useful if the detector is connected to a module or lighting. The duration determines how long the module/lighting should stay ON. For instance, a Lamp Module turns off 100 secs after it has been turned on. The duration can beconfigured to last between 5 to 3600 seconds.
Size: 2 Byte, Default Value: 15

Setting Description
5 - 3600 On-off duration ca be set 5~3600 seconds.

Technical Data

Hardware Platform SD3502
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version HW: 1 FW: 1.00:00.05
Z-Wave Version 6.71.01
Certification ID ZC10-18096247
Z-Wave Product Id 0x0364.0x0002.0x0001
Firmware Updatable Updatable by Consumer via Internet
Color White
Supported Notification Types Home Security
Security V2 S2_UNAUTHENTICATED ,S2_AUTHENTICATED
Frequency XXfrequency
Maximum transmission power XXantenna

Supported Command Classes

  • Association Grp Info
  • Association V2
  • Battery
  • Configuration
  • Device Reset Locally
  • Firmware Update Md V4
  • Manufacturer Specific V2
  • Notification V4
  • Powerlevel
  • Security
  • Security 2
  • Supervision
  • Transport Service V2
  • Version V2
  • Wake Up V2
  • Zwaveplus Info V2

Controlled Command Classes

  • Basic

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network. Controllers are typically Gateways,Remote Controls or battery operated wall controllers.
  • Slave — is a Z-Wave device without capabilities to manage the network. Slaves can be sensors, actuators and even remote controls.
  • Primary Controller — is the central organizer of the network. It must be a controller. There can be only one primary controller in a Z-Wave network.
  • Inclusion — is the process of adding new Z-Wave devices into a network.
  • Exclusion — is the process of removing Z-Wave devices from the network.
  • Association — is a control relationship between a controlling device and a controlled device.
  • Wakeup Notification — is a special wireless message issued by a Z-Wave device to announces that is able to communicate.
  • Node Information Frame — is a special wireless message issued by a Z-Wave device to announce its capabilities and functions.