This is a
Pressing On/Off button three times within 1.5seconds will enter inclusion mode.
| Reset to factory default |
|
| Inclusion | Pressing On/Off button three times within 1.5seconds will enter inclusion mode. |
| Exclusion | Pressing On/Off button three times within 1.5 seconds will enter exclusion mode. |
| NIF | XXXNIF |
| Wakeup | XXXWakeupDescription |
| Protection | XXXProtection |
| FirmwareUpdate | XXXFirmwareUpdate |
| SetAssociation | XXXSetAssociation |
| Group Number | Maximum Nodes | Description |
|---|---|---|
| 1 | 5 | On/Off righ switch (Lifeline) |
| 2 | 5 | On/Off left switch |
| 3 | 5 | On/Off dopple klick righ switch |
| 4 | 5 | All On/Off |
Size: 1 Byte, Default Value: 1
| Setting | Description |
|---|---|
| 0 | off |
| 1 | on |
Size: 1 Byte, Default Value: 1
| Setting | Description |
|---|---|
| 0 | off |
| 1 | on |
Size: 1 Byte, Default Value: 0
| Setting | Description |
|---|---|
| 0 - 1 | Invert switch |
| Setting | Description |
|---|---|
| 0 | Off |
| 1 | 1 second |
| 2 | Constantly |
You may wish to disable transmitting commands to Z-Wave devices that are in Group 4 without “disassociating” those devices from the group. Setting parameter 5 to the value of 1 will stop the switch from transmitting to devices that are “associated” into Group 4. Size: 1 Byte, Default Value: 0
| Setting | Description |
|---|---|
| 0 | sending |
| 1 | not sending |
| Dimensions | 0.0800000x0.0800000x0.0380000 mm |
| Weight | 87 gr |
| Hardware Platform | ZM5202 |
| EAN | 695917446647 |
| IP Class | IP IP 20 |
| Voltage | 230 V |
| Load | 1380 W x 2 |
| Device Type | Two channel wall switch |
| Generic Device Class | Binary Switch |
| Specific Device Class | Binary Power Switch |
| Firmware Version | 02.00 |
| Z-Wave Version | 04.05 |
| Z-Wave Product Id | 0x0118.0x0003.0x0001 |
| Frequency | Europe - 868,4 Mhz |
| Maximum transmission power | 5 mW |