This is a
Pressing any sequence of click on the integrated button.
| Reset to factory default | Press 6 consecutive clicks on the integrated button. |
| Inclusion | Pressing any sequence of click on the integrated button. |
| Exclusion | Pressing any sequence of click on the integrated button. |
| NIF | XXXNIF |
| Wakeup | XXXWakeupDescription |
| Protection | XXXProtection |
| FirmwareUpdate | XXXFirmwareUpdate |
| SetAssociation | XXXSetAssociation |
| Group Number | Maximum Nodes | Description |
|---|---|---|
| 1 | 8 | Lifeline |
| 2 | 8 | Controls relays or dimmers |
| 3 | 8 | Controls relays or dimmers |
| 4 | 8 | Controls relays or dimmers |
Define which sequences of click control the local load. Size: 1 Byte, Default Value: 3
| Setting | Description |
|---|---|
| 0 | Local Control disabled |
| 1 | 1 click control the local load |
| 2 | 2 clicks control the local load |
| 3 | 1 clicks and 2 clicks control the local load |
Size: 1 Byte, Default Value: 100
| Setting | Description |
|---|---|
| 50 - 100 | 50-100% opening level (100% correspond to completely open) |
Size: 1 Byte, Default Value: 0
| Setting | Description |
|---|---|
| 0 - 49 | 0-49% opening level (0 correspond to completely closed) |
Defines the actions to be carried out on the associated devices in terms of Basic Set. Size: 1 Byte, Default Value: 255
| Setting | Description |
|---|---|
| 0 | Off |
| 1 - 99 | Dimming purpose |
| 255 | ON |
Defines the actions to be carried out on the associated devices in terms of Basic Set. Size: 1 Byte, Default Value: 255
| Setting | Description |
|---|---|
| 0 | Off |
| 1 - 99 | Dimming purpose |
| 255 | ON |
Defines the actions to be carried out on the associated devices in terms of Basic Set. Size: 1 Byte, Default Value: 255
| Setting | Description |
|---|---|
| 0 | Off |
| 1 - 99 | Dimming purpose |
| 255 | ON |
Defines the actions to be carried out on the associated devices in terms of Basic Set. Size: 1 Byte, Default Value: 255
| Setting | Description |
|---|---|
| 0 | Off |
| 1 - 99 | Dimming purpose |
| 255 | ON |
Defines the actions to be carried out on the associated devices in terms of Basic Set. Size: 1 Byte, Default Value: 255
| Setting | Description |
|---|---|
| 0 | Off |
| 1 - 99 | Dimming purpose |
| 255 | ON |
Defines the actions to be carried out on the associated devices in terms of Basic Set. Size: 1 Byte, Default Value: 255
| Setting | Description |
|---|---|
| 0 | Off |
| 1 - 99 | Dimming purpose |
| 255 | ON |
| Setting | Description |
|---|---|
| 0 | Calibration to be done in automatic mode |
| 1 | Calibration has been done |
| 2 | Calibration to be done in manual mode |
Defines the level of power consumption under which the motor is considered in idle state Size: 2 Byte, Default Value: 1000
| Setting | Description |
|---|---|
| 0 - 3000 | Expressed in hundredths of Watt (ex. 3000=30 Watt) |
Defines the time after which, a power consumption lower than the PLIMIT (the power defined in parameter No. 21) is considered as reaching the limit switch Size: 1 Byte, Default Value: 30
| Setting | Description |
|---|---|
| 0 | Limit Switch ignored |
| 1 - 127 | Expressed in tenths of seconds |
| Dimensions | 37x37x17 mm mm |
| Weight | 26.6 gr |
| Hardware Platform | ZM5101 |
| EAN | 8059265060092 |
| IP Class | IP 20 |
| Voltage | 230 V |
| Load | 1200 W |
| Device Type | Roller Shutter |
| Generic Device Class | Multilevel Switch |
| Specific Device Class | Motor Control Device (C) |
| Firmware Version | 01.00 |
| Z-Wave Version | 06.04 |
| Z-Wave Product Id | 0x0149.0x1214.0x0800 |
| Frequency | Europe - 868,4 Mhz |
| Maximum transmission power | 5 mW |