This is a
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Thermostatic Radiator Valves (TRVs) sense the air temperature around them and regulate the flow of water through the radiator which they are fitted to.They can be set at a level that gives you the room temperature you want. These settings may have to be different in each room, and you can set the TRVs to suit each room and then leave them to do their job.The device can be set temperature by manual or by gateway.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | -When the unit is powered up first time, the unit will send a Notification Report and Clock report to the node of Group 1.-When the battery level of the unit drops to an unacceptable level, the unit will emit Battery report to the nodes of Group 1.-When performing Factory Reset the unit will send Device Reset Locally Notification to the node of Group1.-The unit will send Sensor Multilevel Report to the node of Group 1 every two hours.-When changing mod of the unit, it will send Thermostat Mode Report to the node of Group 1.-When changing target value of temperature, the unit will send Thermostat Setpoint Report to the node of Group 1.-When changing the state of button lock, the unit will send Protection Report to the node of Group |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Temperature Auto Report period setting Size: 2 Byte, Default Value: 120
Setting | Description |
---|---|
1 - 255 | minutes |
Manual Override takeover period Size: 1 Byte, Default Value: 8
Setting | Description |
---|---|
1 - 48 | 1~48, means 30mins to 24hrs (8=4hrs) |
Temperature offset for internal sensor Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
-80 - 80 | -80~+80 Offsets the measured temperature by -8.0~+8.0 |
Maximum Set point value Size: 1 Byte, Default Value: 35
Setting | Description |
---|---|
5 - 35 | 5~35 for 5~35 |
Minimum Set point value Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
5 - 35 | 5~35 for 5~35 |
Frost protection temperature Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
5 - 15 | 5~15 for 5~15 |
Open window detect function Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | 0: Disable 1: Enable |
Open window detect time period Size: 1 Byte, Default Value: 15
Setting | Description |
---|---|
2 - 30 | minutes |
Open window detect temperature drop setting Size: 1 Byte, Default Value: 4
Setting | Description |
---|---|
4 - 8 | 4=2 , 5=2.5 6= 3, 7=3.5, 8=4 |
Open window detect delay time select Size: 1 Byte, Default Value: 30
Setting | Description |
---|---|
10 - 60 | minutes |
Hardware Platform | SD3502 |
Device Type | Thermostat - HVAC |
Network Operation | Listening Sleeping Slave |
Firmware Version | HW: 1 FW: 1.01:00.00 |
Z-Wave Version | 6.81.03 |
Certification ID | ZC10-22067099 |
Z-Wave Product Id | 0x0060.0x0015.0x0001 |
Thermostat Modes | Energy Save HeatHeat |
Thermostat HVAC Systems Supported | Heat Only |
Thermostat Power Source | Battery |
Firmware Updatable | Updatable by Consumer by RF |
Security V2 | S2_UNAUTHENTICATED ,S2_AUTHENTICATED |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |