Quickstart

This is a secure Remote Control - AV for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged. To add this device to your network execute the following action:
Put the Z-Wave Controller in inclusion mode. Hold down the central key, then press the top-right key 3 times within 1.5 seconds to enter inclusion mode. Aftersuccessfulinclusion,thedevicewillwaketoreceivethe setting command from Z-Wave Controller in about 20 seconds.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

Zipato Z-Wave Remote is a simple controller for controlling AV device through Z-Wave-to-IR extender, and it can also control 8 ON/OFF lighting groups via basic set, based on Z-Wave technology. It is the Z-Waveplusproduct,itsupportthesecurity,OTA...allthe newestfeatures of the Z-Wave technology.

Reset to factory default Usethisprocedureonlyintheeventthattheprimary controller is lost or otherwise inoperable.Hold down the central key, then press the top-right key 4 times within 1.5 seconds and during 4th press, hold the key until LED lights up. After 3 seconds the LED will turn OFF, and after next 2 seconds, release the tamper key. If successful, the LED will light ON for second. Otherwise, the LED will flash once. IDs are excluded and all settings will reset to factory default.
Inclusion Put the Z-Wave Controller in inclusion mode. Hold down the central key, then press the top-right key 3 times within 1.5 seconds to enter inclusion mode. Aftersuccessfulinclusion,thedevicewillwaketoreceivethe setting command from Z-Wave Controller in about 20 seconds.
Exclusion Put the Z-Wave Controller in exclusion mode. Hold down the central key, then press the top-right key 3 times within 1.5 seconds to enter exclusion mode. Node ID has been excluded.
NIF XXXNIF
Wakeup After the device is added to the network, it will wake-up once per day in default. When it wakes up it will broadcast the Wake Up Notification message to the network, and wake-up 10 seconds to receive the setting commands. To wake-up the device immediately, please hold down the central key, then press the top-right key once within. The device will wake-up for 10 seconds.
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 4 Z-Wave Plus Lifeline
2 4 Lighting group control
3 4 Lighting group control
4 4 Lighting group control
5 4 Lighting group control
6 4 Lighting group control
7 4 Lighting group control
8 4 Lighting group control
9 4 Lighting group control

Configuration Parameters

Parameter 10: Auto Report Battery Time

The interval time for auto report the battery level.
Size: 1 Byte, Default Value: 12

Setting Description
0 - 127 0 means turn off auto report battery.Each tick means 30 minutes.The default value is 12(6 hours).

Parameter 2: Basic Set Level

Setting the BASIC command value to turn on the light. The xFF(-1) means turn on the light. For dimmer equipment 1 to 100 means the light strength. 0 means turn off the light.
Size: 1 Byte, Default Value: -1

Setting Description
-128 - 127 Setting the BASIC command value to turn on the light.

Parameter 7: Customer Function

Customer function switch, using bit control.
Size: 1 Byte, Default Value: 0

Setting Description
1 Switch AV control/ Lighting group control.

Parameter 82: Association Group 2 Basic Set Level

Setting the BASIC command value to turn on the light in the association group 2.
Size: 1 Byte, Default Value: 0

Setting Description
-128 - 127 0 means using the value of configuration 2 to set.

Parameter 83: Association Group 3 Basic Set Level

Setting the BASIC command value to turn on the light in the association group 3.
Size: 1 Byte, Default Value: 0

Setting Description
-128 - 127 0 means using the value of configuration 2 to set.

Parameter 84: Association Group 4 Basic Set Level

Setting the BASIC command value to turn on the light in the association group 4.
Size: 1 Byte, Default Value: 0

Setting Description
-128 - 127 0 means using the value of configuration 2 to set.

Parameter 85: Association Group 5 Basic Set Level

Setting the BASIC command value to turn on the light in the association group 5.
Size: 1 Byte, Default Value: 0

Setting Description
-128 - 127 0 means using the value of configuration 2 to set.

Parameter 86: Association Group 6 Basic Set Level

Setting the BASIC command value to turn on the light in the association group 6.
Size: 1 Byte, Default Value: 0

Setting Description
-128 - 127 0 means using the value of configuration 2 to set.

Parameter 87: Association Group 7 Basic Set Level

Setting the BASIC command value to turn on the light in the association group 7.
Size: 1 Byte, Default Value: 0

Setting Description
-128 - 127 0 means using the value of configuration 2 to set.

Parameter 88: Association Group 8 Basic Set Level

Setting the BASIC command value to turn on the light in the association group 8.
Size: 1 Byte, Default Value: 0

Setting Description
-128 - 127 0 means using the value of configuration 2 to set.

Parameter 89: Association Group 9 Basic Set Level

Setting the BASIC command value to turn on the light in the association group 9.
Size: 1 Byte, Default Value: 0

Setting Description
-128 - 127 0 means using the value of configuration 2 to set.

Technical Data

Hardware Platform SD3502
Device Type Remote Control - AV
Network Operation Portable Slave
Firmware Version HW: 1 FW: 1.12:01.05
Z-Wave Version 6.51.02
Certification ID ZC10-17065643
Z-Wave Product Id 0x0131.0x0008.0x001D
Supported Notification Types Emergency Alarm
Frequency XXfrequency
Maximum transmission power XXantenna
CEPT (Europe)Remote Control - AV