Put the Z-Wave Controller in inclusion mode. Hold down the central key, then press the top-right key 3 times within 1.5 seconds to enter inclusion mode. Aftersuccessfulinclusion,thedevicewillwaketoreceivethe setting command from Z-Wave Controller in about 20 seconds.
Zipato Z-Wave Remote is a simple controller for controlling AV device through Z-Wave-to-IR extender, and it can also control 8 ON/OFF lighting groups via basic set, based on Z-Wave technology. It is the Z-Waveplusproduct,itsupportthesecurity,OTA...allthe newestfeatures of the Z-Wave technology.
Reset to factory default | Usethisprocedureonlyintheeventthattheprimary controller is lost or otherwise inoperable.Hold down the central key, then press the top-right key 4 times within 1.5 seconds and during 4th press, hold the key until LED lights up. After 3 seconds the LED will turn OFF, and after next 2 seconds, release the tamper key. If successful, the LED will light ON for second. Otherwise, the LED will flash once. IDs are excluded and all settings will reset to factory default. |
Inclusion | Put the Z-Wave Controller in inclusion mode. Hold down the central key, then press the top-right key 3 times within 1.5 seconds to enter inclusion mode. Aftersuccessfulinclusion,thedevicewillwaketoreceivethe setting command from Z-Wave Controller in about 20 seconds. |
Exclusion | Put the Z-Wave Controller in exclusion mode. Hold down the central key, then press the top-right key 3 times within 1.5 seconds to enter exclusion mode. Node ID has been excluded. |
NIF | XXXNIF |
Wakeup | After the device is added to the network, it will wake-up once per day in default. When it wakes up it will broadcast the Wake Up Notification message to the network, and wake-up 10 seconds to receive the setting commands. To wake-up the device immediately, please hold down the central key, then press the top-right key once within. The device will wake-up for 10 seconds. |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 4 | Z-Wave Plus Lifeline |
2 | 4 | Lighting group control |
3 | 4 | Lighting group control |
4 | 4 | Lighting group control |
5 | 4 | Lighting group control |
6 | 4 | Lighting group control |
7 | 4 | Lighting group control |
8 | 4 | Lighting group control |
9 | 4 | Lighting group control |
The interval time for auto report the battery level. Size: 1 Byte, Default Value: 12
Setting | Description |
---|---|
0 - 127 | 0 means turn off auto report battery.Each tick means 30 minutes.The default value is 12(6 hours). |
Setting the BASIC command value to turn on the light. The xFF(-1) means turn on the light. For dimmer equipment 1 to 100 means the light strength. 0 means turn off the light. Size: 1 Byte, Default Value: -1
Setting | Description |
---|---|
-128 - 127 | Setting the BASIC command value to turn on the light. |
Customer function switch, using bit control. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Switch AV control/ Lighting group control. |
Setting the BASIC command value to turn on the light in the association group 2. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
-128 - 127 | 0 means using the value of configuration 2 to set. |
Setting the BASIC command value to turn on the light in the association group 3. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
-128 - 127 | 0 means using the value of configuration 2 to set. |
Setting the BASIC command value to turn on the light in the association group 4. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
-128 - 127 | 0 means using the value of configuration 2 to set. |
Setting the BASIC command value to turn on the light in the association group 5. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
-128 - 127 | 0 means using the value of configuration 2 to set. |
Setting the BASIC command value to turn on the light in the association group 6. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
-128 - 127 | 0 means using the value of configuration 2 to set. |
Setting the BASIC command value to turn on the light in the association group 7. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
-128 - 127 | 0 means using the value of configuration 2 to set. |
Setting the BASIC command value to turn on the light in the association group 8. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
-128 - 127 | 0 means using the value of configuration 2 to set. |
Setting the BASIC command value to turn on the light in the association group 9. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
-128 - 127 | 0 means using the value of configuration 2 to set. |
Hardware Platform | SD3502 |
Device Type | Remote Control - AV |
Network Operation | Portable Slave |
Firmware Version | HW: 1 FW: 1.12:01.05 |
Z-Wave Version | 6.51.02 |
Certification ID | ZC10-17065643 |
Z-Wave Product Id | 0x0131.0x0008.0x001D |
Supported Notification Types | Emergency Alarm |
Frequency | XXfrequency |